TM 5-3825-213-20
Servicing.
b.
6140-200-15.
(1) Perform
before-operation services
Warning: Electrolyte contains sulphuric acid
(TM 5-3825-213-10).
and causes severe skin burns. If electrolyte comes
in contact with the skin or clothing wash the
engines and fill with proper lubricant
contaminated area immediately with clear water and
(LO 5-3825-213-20).
change clothing.
(3) Fill the batteries with electrolyte in
Table I. Specific Gravity Temperature Corrections
-65 F.
-40 F.
-20 F.
20 F.
40 F.
80 F.
100 F.
110 F.
Available cranking power
10 F.
0 F
120 F.
50%
1.277
1.267
1.259
1.255
1.251
1.243
1.236
1.220
1.213
1.209
1.205
58.3%
1.287
1.277
1.269
1.265
1.261
1.253
1.246
1.230
1.223
1.219
1.215
66.6%
1.297
1.287
1.279
1.275
1.271
1.263
1.256
1.240
1.233
1.229
1.225
75%
1:307
1.297
1.289
1.285
1.281
1.273
1.266
1.250
1.243
1.239
1.235
83.3%
1.317
1.307
1.299
1.295
1.291
1.283
1.276
1.260
1.252
1.248
1.245
91.6%
1.327
1.317
1.309
1.305
1.301
1.294
1.286
1.270
1.262
1.258
1.255
100%
1.338
1.328
1.320
1.316
1.312
1.304
1.296
1.280
1.272
1.268
1.265
(4) Install the battery cables as illustrated
Refer to TM 9-207 for cold weather
(5) Inspect the cooling system for leaks
operation.
and insecure mounting.
Fill the
Table II. Freezing Points, Composition, and Specific Gravities of Military
Antifreeze materials
Lowest
Pints of
expected
inhibited
Compound, Antifreeze
Ethylene glycol
2
coolant solution
ambient
glycol per
Arctic
temp
gal of
specific gravity
at 68F
F
1
3
coolant
+20
1 1/2
Issued full strength and ready mixed for 0F. to 65F
1.022
+10
2
temperatures for both initial installation and re-
1.036
0
2 3/4
plenishment of losses
1.047
-10
3 1/4
1.055
-20
3 1/2
1.062
-30
4
1.067
-40
4 1/4
1.073
-50
Artic Anti-
DO NOT DH JTE WITH WATER OR ANY OTHER
-60
freeze pre-
SUBSTANCE.
-75
ferred
1
Maximum protection is obtained at 60 percent by volume, that is 4.8 pints of ethylene glycol per gallon of solution.
2
Military Specification MIL-C 11755 Arctic type. nonvolatile antifreeze compound is intended for use in cooling system of
liquid-cooled internal combustion engines for protection against freezing primarily in Arctic regions where the ambient
temperature remains for extended periods of time close to -40 F. or drops below, to as low as -90 F.
3
Use an accurate hydrometer. To test hydrometer, use 1 part ethylene glycol antifreeze to 2 parts water. This should produce
a hydrometer reading of 0F.
Note. Fasten a tag near the radiator fillercap indicating the type of antifreeze, and amount.
c. Install the plow (TM 5-3825-213-10).
9. Installation of Separately Packed
d. Install the plow hydraulic lines from the
Components
carrier to the quick disconnect panel on the plow (fig. 6).
b. Install the snow chute hydraulic lines as
16